Phase 2

In ePBRAT, Phase 2 (Operational Delivery Review) can be done within 3 days prior to anticipated ignition and when the burn is moving from “Ready” to “Authorisation Required” status.

Once Phase 1 of the risk assessment is complete, user is redirected to the ePBRAT landing page. User can either:

  1. Click on the Date the risk assessment was created/updated to continue with completing Phase 2, or
  2. Click on Create New to create a new risk assessment record.

Create New Risk Assessment

User clicks on Create New.

From Phase 1

If the previously added Phase 1 data is not valid and new approvals are required, user can select from Phase 1 option and click OK.

A new risk assessment record is created, and user is navigated to the Phase 1 form.

Note: Please ensure to read the conditions valid for creating a new risk assessment record from Phase 1.

From Phase 2

If the previously approved Phase 1 form is still valid and no changes are required, user can select from Phase 2 option and click OK.

User will be navigated to the Phase 2 form.

Notes:

  1. All the data entered previously for Phase 1 will be copied over to the new risk assessment record.
  2. The previously created risk assessment record will become read-only.
Burns and Works Details

Phase 2 – Operational Delivery Review (Within 24-48 hours)

Notes:

Intended Ignition Date and Time has a lower and upper threshold based on the current date and time. Users are not allowed to enter date and time which doesn’t fall in this duration.

Lower threshold > Current date and time + 16 hours

Higher threshold ≤ Current date + 3 days

If preparation of ePBRAT is completed for a burn with an ignition date beyond 48 hours, a comment must be entered in the ePBRAT justifying the early completion.

 

FDI value is GFDI if grass prescription is selected. FDI value is FFDI if forest prescriptions are selected.

 

FDI: Highest value in the time range will be displayed for FFDI or GFDI based on prescription selected.

Temperature: Highest value in the time range will be displayed.

Relative Humidity (%): Lowest value in the time range will be displayed.

Wind Speed at 10m: Highest value in the time range will be displayed.

Curing: Highest value in the time range will be displayed if grass prescription is selected.

Review and Approvals